| Model Name/Number | Fluke 106 |
| Brand | Fluke |
| Resistance Range | 40-400Ohms |
| Diode Test | Yes |
| AC Volts Range | 6-600 V |
| Diode Test Range | 2.000 V |
| Capacitance Range | 50.00 nF-1000 microF |
| Frequency | 50.00 Hz-100.0 kHz |
| Duty Cycle | 1 % to 99 % |
| Display | 6000 counts,updates 3/sec (LCD) |
| Battery Type | 2 AAA,NEDA 24A,IEC LR03 |
| Battery Life | 200 hours minimum |
Pri
ce Range: MRP+10% Tax
| unction | Range | Resolution | Accuracy | |
| AC Volts (40 Hz to 500Hz)1 |
6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
1.0 % + 3 | |
| DC Volts | 6.000 V 60.00 V 600.0 V |
0.001 V 0.01 V 0.1 V |
0.5 % + 3 | |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
| Diode Test2 | 2.000 V | 0.001 V | 10 % | |
| Resistance (Ohms) |
400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
|
| Capacitance3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
|
| Frequency4 Hz (10 Hz – 100 kHz) |
50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA | |
| Duty Cycle4 | 1 % to 99 % | 0.1 % | NA | |
| AC Current (40 Hz to 200 Hz) |
4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |
| DC Current | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | |